How should the self-priming pump be installed and what should be noted?

Self-priming pump is a self-priming centrifugal pump, which has the advantages of compact structure, convenient operation, stable operation, easy maintenance, high efficiency, long life, and strong self-priming capacity. The pipeline does not need to be installed with a bottom valve, and it is only necessary to ensure that a quantitative fluid is stored in the pump body before work. Different liquids can use self-priming pumps of different materials. Then I bought a self-priming pump, how to install it, and what should I pay attention to? Here are some pump owners who will tell us how to install the self-priming pump.

Self-priming pump installation precautions

1. Before installing the self-priming pump, you should carefully check whether the bolts of the self-priming pump are loose and there is no foreign matter falling into the pump body, so as not to damage the impeller when the self-priming pump is running.

2. Put the self-priming pump on the concrete foundation, put an isolation pad between the bottom plate and the foundation, and adjust the level of the isolation pad to find the level of the pump, and tighten the bolts after adjusting.

3. Before installing the self-priming pump, the appropriate concrete foundation should be prepared by the fire pump manufacturer according to the basic size of the self-priming pump, and the anchor bolts must be embedded in the concrete foundation process. Concrete foundation refers to the large self-priming pump products, and small self-priming pumps do not need to be used for concrete foundation.

4. When there is a dust cover at the inlet and outlet of the self-priming pump, the dust cover should be removed and connected to the pipeline. It should be noted that if the self-priming pump product that absorbs the fastest water is used, the outlet pipe must Turning can only be done after 1 meter vertical, otherwise the water in the pump body can be easily drained during the self-priming process.

5. For the convenience of maintenance and safe use, a regulating valve should be installed on the inlet and outlet pipes of the self-priming pump, and a pressure gauge should be installed between the outlet valve and the pump to ensure that the fire pump manufacturer has certified the self-priming pump at its rated capacity. It can be used within the range of flow and head, so that the self-priming pump can run normally and prolong the service life of the self-priming pump.

6. Before the self-priming pump is installed and started, the pump shaft should be dialed to fill the pump cavity with liquid at the same time, so that the liquid fills the pump cavity to achieve the purpose of exhausting. Check the pump for leakage, and the impeller should have no frictional sound or stuck. If there is friction or stuck, the pump should be disassembled, check the specific cause and solve the problem.

7. The suction and outlet pipes of self-priming pumps cannot be supported by water pumps. Instead, a separate support is needed to support the inlet and outlet pipes. The diameter of the inlet and outlet pipes should match the diameter of the self-priming pump, especially the inlet pipes cannot Larger and larger will affect the self-priming height of the self-priming pump. If the inlet pipe of the self-priming pump is reduced during installation, the outlet pipe must also be reduced. We recommend that it is better to configure the corresponding pipe according to the factory standard caliber.

End Cap For Ball Mill

End Cap For Ball Mill

Product introduction:

The end cover is a rear cover installed behind the motor housing.

800

Workshop show



12334

Factory Equipments


Luoyang Hong Xin Heavy Co., LTD. is located in Luoyang Xin'an Industrial Park, Luoyang Hongxin Heavy Machinery Co., Ltd is an enterprise featured with industrial designing, processing and manufacturing, which is qualified for import-export trade. Covering an area of 15,000 square meters and holding an annual production value of 80 million RMB, the company of 20 million RMB registered capital has total 100 staff members, among which there are 20 engineering technicians owning senior and medium professional titles and 40 intermediate and senior technicians capable of product designing and developing.

Hongxin is dedicated to produce reducers, hoists, crushers, Ball Grinding Mills and the equipments of screening, coal washing, metallurgy and cement, and replacement parts. Meanwhile, we provide the perform maintenance service for various series of equipments. There are 52 large-scale equipments applied into the manufacturing process, such as T200 CNC floor boring and milling machine, YK 73125 CNC molding gear grinding machine, YK322B CNC molding gear grinding machine, Y3200 gear hobbing machine, Y1600 CNC gear sharper, 4m vertical lathe, 6.3m CNC vertical lathe, T110 CNC boring machine, and 52 middle-sized productive and assistive equipments, which integrate strong manufacturing and processing capability with complete managing system of production and technology, quality management system and comprehensive testing measures

certificates


Contacts





End Cap For Ball Mill

End Cap For Ball Mill,Casting End Cap for Ball Mill,Forging End Cap For Ball Mill,Ball Mill Parts End Cap

Luoyang Hongxin Heavy Machinery CO., TLD. , https://www.hxreducer.com

Posted on