Piston Pump & Valve Integtated Module - 500UL Pump & 2-Way Valve

Model NO.: 5005-12-BUP/64C-018
Start Up: Electric Pump
Type: Positive-Displacement Pump
Application: Clarified Water Pump, Chemical Pump
Industry: Mechanical Pump
Media: Water, Reagent. etc.
Performance: No Leakage Pump
Theory: Axial Flow Pump
Trademark: Keyto
Transport Package: Bulk Packing
Specification: 500uL dispense volume
Origin: China
HS Code: 8413503190
Model NO.: 5005-12-BUP/64C-018
Start Up: Electric Pump
Type: Positive-Displacement Pump
Application: Clarified Water Pump, Chemical Pump
Industry: Mechanical Pump
Media: Water, Reagent. etc.
Performance: No Leakage Pump
Theory: Axial Flow Pump
Trademark: Keyto
Transport Package: Bulk Packing
Specification: 500uL dispense volume
Origin: China
HS Code: 8413503190
Description:
Piston pump & valve integrated module consists of Keyto's 2-way rocker diaphragm type solenoid valve and Keyto's precision piston pump.
It provides precise fluid dispensing for a variety of medical and laboratory instruments.
It reduces the leakage risk as less tubes and connectors installed, and has the high accuracy and consistency. 

Specification:
Max Dispense Volume 500 μL
Piston diameter 7.08 mm
Volume per stroke 0.25 μL
Travel distance 12.7  mm
Distance per stroke 0.00635 mm
Motor step angle 1.8°
Coefficient of variation (CV) <1.2%; <1%
(Measuring when more than 2%; 10%  of total dispense)
Anticipated Life 5 million cycles
Integrated valve matches with 1013 series 2-way solenoid valve 


Installation dimension:







  Description:
Piston pump & valve integrated module consists of Keyto's 2-way rocker diaphragm type solenoid valve and Keyto's precision piston pump.
It provides precise fluid dispensing for a variety of medical and laboratory instruments.
It reduces the leakage risk as less tubes and connectors installed, and has the high accuracy and consistency. 

Specification:
Max Dispense Volume 500 μL
Piston diameter 7.08 mm
Volume per stroke 0.25 μL
Travel distance 12.7  mm
Distance per stroke 0.00635 mm
Motor step angle 1.8°
Coefficient of variation (CV) <1.2%; <1%
(Measuring when more than 2%; 10%  of total dispense)
Anticipated Life 5 million cycles
Integrated valve matches with 1013 series 2-way solenoid valve 


Installation dimension:







 

Closed Cooling Tower

Why say closed cooling tower is energy saving and environmental protection equipment, more and more users are using this kind of equipment to replace the original equipment (open tower), we can through data analysis and comparison, the two energy data accounting can be obvious. Energy consumption is basically two major aspects, one is water, the other is electricity. Both are energy costs that no cooling tower can escape, unless you leave the equipment on.

First of all, look at the consumption of water. Water is generally consumed in two aspects. One is the flying overflow after spraying, and the other is the evaporation consumption of water.

Let's look at the open cooling tower, the spray water of the tower is basically between two and three percent of the overflow rate, if we according to the daily operation of 10 hours, excluding holidays, 280 days of operation. According to the actual open cooling tower flow of 6000 cubic meters per hour to calculate. 6000*2%*10*280= 336,000 tons of water, and the same closed cooling tower, its spray flying overflow is very small, because after all, the spray work is carried out in the tower, almost can be controlled in a few thousandths, we calculate according to 5 thousandths, the same is 10 hours of work, 280 days a year operation, To achieve the same cooling amplitude is basically 4,500 tons per hour of closed cooling tower is enough, then the calculation results: 4,500 *0.5%*10*280= 63,000 tons, it is not difficult to see, because of the different design structure caused by the waste of spraying water resources, more than 200,000 tons of terror. The bigger the pool of the open tower, the more wasted water, because the evaporation area increases, and the closed cooling tower has no pool, so the consumption here is zero. Judging from the price of a ton of water, just such a equipment, a year to solve the capital of hundreds of thousands of enterprises.

Let's look at the comparison of electric energy, electric energy is not different, because they are all through the same power equipment to operate the equipment, the power of the two is similar, the running time is the same, basically the energy consumption is about the same.

To sum up, for the closed cooling tower energy saving accounting can be strong to open the tower out, and, today are advocating energy conservation and environmental protection, this is the general trend, so the closed cooling tower is more and more favored by the majority of users.

Closed Cooling Tower,Closed Circuit Cross Flow,Closed Loop Cooling Tower,Closed Circuit Cooler

Wuxi Ark Fluid Science Technology Co., Ltd. , https://www.fangzhouarkfluid.com

Posted on